Polyfilt CF is a non-metallic multi-cartridge housing for corrosive service. Up to 54 m³/hr at 6 bar.

A multi-cartridge housing from the Polyfilt uPVC range. It takes 2.5" OD cartridges in 10", 20", 30" and 40" lengths, 5 or 9 per vessel, on 2" or 3" uPVC union connections. The locator and closure design prevents internal bypass, and the top locks with stainless steel swing nuts.

Polyfilt CF, catalogue image

Up to 54 m³/hr

Polyfilt CF 5 or 9 filter cartridges, 10" to 40"

Polyfilt CF
Typical flow, 40" × 9
36 to 54 m³/hr
Maximum operating pressure
6 bar at 21 °C
Hydro‑test pressure
11 bar
Temperature
4 to 60 °C
  • Corrosion and rust resistant

    A non-metallic body with resistance to chemicals, UV exposure and atmospheric oxidation.

  • Sealed against internal bypass

    The locator and closure design seats every filter cartridge, so fluid does not pass around it.

  • Up to 54 m³/hr in one vessel

    Nine 40" filter cartridges on a 3" union connection.

  • Moulded construction

    Moulding gives a consistent wall thickness from one housing to the next. Lightweight construction makes filter cartridge change-out simpler.

How it is built

Construction

  1. Moulded body

    The third-generation Polyfilt design, moulded for a consistent wall thickness.

  2. Locator and closure

    Each filter cartridge sits on a locator, and the closure design prevents internal bypass.

  3. Stainless swing nuts

    The top locks with stainless steel swing nuts. The seal is silicone; others on request.

Polyfilt CF, catalogue image
Filter cartridges2.5" OD, DOE or SOE (222 / fin)
Connection2" or 3" uPVC union
LockStainless steel swing nuts

Specifications

Specification table

MaterialsBody, lock, seal

PropertyValue
Housing sump and topEngineering plastic (PVC)
Housing lockStainless steel swing nuts
O-ring / gasketSilicone, others on request

Operating limitsPressure and temperature

PropertyValue
Maximum operating pressure6 bar (87.02 psid) at 21 °C
Hydro-test pressure11 bar (159.5 psid)
Temperature4 °C to 60 °C

SizesTypical flow, connection, dimensions A, B, C, ØD in mm

PropertyValue
10" × 55 to 7.5 m³/hr; 2" union; A 75, B 475 ± 10, C 490, ØD 225
20" × 510 to 15 m³/hr; 2" union; A 75, B 735 ± 10, C 490, ØD 225
30" × 515 to 22.5 m³/hr; 2" union; A 75, B 970 ± 10, C 490, ØD 225
40" × 520 to 30 m³/hr; 2" union; A 75, B 1220 ± 10, C 490, ØD 225
30" × 927 to 40.5 m³/hr; 3" union; A 69, B 1005 ± 10, C 510, ØD 315
40" × 936 to 54 m³/hr; 3" union; A 69, B 1265 ± 10, C 510, ØD 315

Ordering codeBuild the part number field by field

PropertyValue
PatternPOLYFILTCF + filter cartridges + DC + length + end fitting
Filter cartridges5 = 5 filter cartridges; 9 = 9 cartridges
Length10 = 10"; 20 = 20"; 30 = 30"; 40 = 40"
End fittingD = DOE; S = SOE

Dimensions in mm.

Check Polyfilt CF against your duty.

Send the fluid, flow, temperature and the micron rating you need. We will confirm the fit, the size and the housing, or name the line that suits the duty better.

Where it runs

Chemical processing, effluent treatment and corrosive water

Applications

Chemical processing and corrosive fluid filtration; water and wastewater treatment; ETP, STP and ZLD systems; plating, pickling and surface treatment.

Filter cartridges to fit

2.5" OD filter cartridges, 10" to 40" long, DOE or SOE 222 with fin. Send us the cartridge you run and we confirm the fit.

Industry pages

The process stages it serves, and what it protects there.

Readily available, with a scheduled delivery service for the annual cartridge requirement.

Request the catalogues

Questions

Polyfilt CF: common questions

Which filter cartridges fit Polyfilt CF?
2.5" OD filter cartridges, 10", 20", 30" or 40" long, DOE or SOE (222 with fin).
What are the pressure and temperature limits?
6 bar maximum operating pressure at 21 °C, 11 bar hydro-test, and 4 °C to 60 °C.

Resources for this line

Datasheets and catalogue pages that cover Polyfilt CF, sent by email on request.

  • Polyfilt uPVC CF, BF and HF2.7 MB
    Request

Open the full library

Related products and tools

  • Above 60 °C

    Clary-T Vent is rated to 135 °C.

  • Filtration Academy

    How to choose a filter housing: the seal that holds the filter cartridge rating, flow and connections, pressure and temperature, material and finish, and design code. With Gopani housing figures.

Request a quote

Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani filter cartridge.

Request a quote
  • Request the catalogues

    The Polyfilt CF catalogue and the rest of the filter housings and systems range, sent by email on request.

    Go to the catalogues
  • Compare the filter housings and systems range

    Clary-T CF, Clary-T Sanitary Filter Housings, Clary-T Strainers, Clary-T HF, Clary-T Vent, Clary-T BF, Clary-T LF, ClarySEA FRP housing, Polyfilt BF, Polyfilt HF, Plastofilt CF, Plastofilt BF, Catalyst recovery systems

    Open the family

Request a catalogue

Tell us who you are and where to send it. Our team emails the catalogue to you.

By sending this you agree to our Privacy notice.