Skip to content

Sintered Metal Filter Cartridges

Clarysynt replacement elementsreplace the sintered elements in the housings and systems you already run, whoever built them. Made to your drawing, sample or dimensions, 0.2 to 25 µm.

Clarysynt powder sintered filter cartridges, candles, tubes and discs made to the diameter, length and end connection of the element you run now, for the filter housings, catalyst filters and backwash systems already installed in your plant, whoever built them. Send a drawing, a sample or the dimensions of the old element with your process conditions, and an application engineer confirms the Clarysynt element that fits and quotes it.

Clarysynt powder sintered stainless steel candle with a threaded end fitting and hex nut, the end cap engraved with the Gopani part number

0.2 to 25 µm

Clarysynt replacement elements OD 50 to 75 mm, 10" to 60"

Clarysynt replacement elementsRequest a quote
What you send
Drawing, sample or dimensions
Retention rating
0.2 to 25 µm
Diameter
50 to 75 mm (± 1 mm)
End connections
21 coded, others on request
  • Made to the element you run

    Diameter, length, end connection and seal are taken from your drawing, sample or dimensions, so the element is made for the housing or tube sheet already installed.

  • Standard sizes first

    Clarysynt PM comes in 50, 54, 60, 63.5, 65 and 75 mm diameters, 10" to 60" lengths and 21 coded end connections. Other sizes and connections are made on request.

  • Materials for the process

    SS 316L media, support and hardware, with Hastelloy C-22 or C-276 as an option. Nickel based alloys and titanium are considered where stainless steel is not enough, subject to confirmed availability.

  • Each element tested

    Integrity, dimensions, largest and average pore size and permeability are tested on each element, with periodic corrosion and ultrasonic testing.

How it is built

From your old element to a Clarysynt quotation

  1. Send what you have

    A drawing of the element, a sample, or its dimensions and part number. A photograph of the end connection and the label helps.

  2. Geometry is matched

    An application engineer reads the diameter, length, end connection, seal arrangement and retention rating, and checks them against the Clarysynt range.

  3. Process is confirmed

    Fluid or gas, flow, temperature, allowable pressure drop and cleaning method decide the material and rating. Final material selection is confirmed against the complete process chemistry.

  4. Quotation

    You receive the Clarysynt part number and a quotation. Where no standard size fits, the element is engineered to order: define, design, prototype, validate, manufacture.

Sintered metal candles on a tube sheet, for catalyst filtration
Sintered candles on a tube sheet, for catalyst filtration.
MediaPowder sintered metal
MaterialsSS 316L; Hastelloy C-22 or C-276
SealsSilicone, FKM, Buna-N, EPDM, PTFE

Specifications

Specification table

What can be replacedElement forms Gopani makes

PropertyValue
Filter cartridges and candlesFor reusable or cleanable filtration systems
Filter tubesPlain or fitted porous tubes; Clarysynt PM filter tubes, ordering code CSPWT
Catalyst trapping tubesUp to 1600 mm long; 50 to 60, 63.5 and 75 mm OD; 0.2 to 50 micron
Discs and platesDiscs 5 to 500 mm in diameter, from 1.5 mm thick, 0.2 to 50 micron
Cups, cones and fritsShaped components, and column and instrument frits

Clarysynt PM standard rangeFilter cartridges and tubes

PropertyValue
Diameter50, 54, 60, 63.5, 65, 75 mm (± 1 mm)
Lengths10", 20", 30", 40", 50", 60"
Retention rating0.2, 0.5, 1, 2, 5, 10, 20, 25 µm
Maximum forward pressure1.5 MPa (15 bar) to 2.5 MPa (25 bar)
Maximum reverse pressure0.3 MPa (3 bar) to 0.9 MPa (9 bar)
Operating temperature-192 °C to 900 °C, depending on the seal material

End connectionsAs listed, others on request

PropertyValue
Open endsDOE (double open end)
Single open end, O-ring226 (Code-7) and 222, with fin or flat end
Threaded1/2", 1", 1 3/8", 2" and G1/4" BSP (M); 1/2" and 1" NPT (M); M20, M30, M40
Threaded with two O-rings1" and 2" BSP (M)
Also available4" and 6" threads, BSPT, 215, 220 and flanged

Materials and sealsSelected for the process

PropertyValue
Media, support, hardwareSS 316L. Hastelloy C-22 or C-276 optional
Other alloys304L stainless steel for non-aggressive service; nickel based alloys, titanium and special alloys subject to confirmed availability
O-ringsSilicone, FKM (Viton), Buna-N, EPDM, PTFE
Element testsIntegrity, dimensions, largest and average pore size, permeability; periodic corrosion and ultrasonic testing

What we need to quoteSend as many as you have

PropertyValue
The old elementDrawing, sample, or dimensions and part number, with a photograph of the end connection and label
DimensionsOuter diameter, overall length, end connection and seal arrangement
RatingRetention rating of the element you run now
ProcessFluid or gas, flow rate, operating temperature, operating and allowable differential pressure
CleaningBackwash, blowback, chemical, ultrasonic or thermal, and how often
InstallationHousing or system make and model, number of elements, tube sheet drawing if you have one, and quantity

Source: Gopani Clarysynt PM catalogue, 2026, PDF pages 3 to 7; Gopani sintered porous metal filters catalogue (all products), 2026, PDF pages 5, 7, 10 and 14; Hydrogen peroxide catalogue, 2026, PDF pages 5 and 9; Catalyst Recovery catalogue, 2026, PDF page 3 (element tests).

Where it runs

Where replacement elements are used, and how to order one

Where they are used

Catalyst filters after hydrogenation, in batch reactors and in continuous hydrogenation loops, where the elements trap the catalyst and are backwashed for recovery. Steam, compressed air and gas, hot liquids and aggressive solvents. The element is made to fit the housing or system already installed, whoever built it.

What we need to make one

A drawing, a sample or the dimensions of the element you run now; the end fitting and thread; the retention rating; the alloy, SS 316L or Hastelloy C-22 or C-276; and the duty: fluid or gas, flow, temperature, allowable pressure drop and cleaning method.

What you receive

A Clarysynt part number and a quotation for an element made to fit your housing or tube sheet. Each element is tested for integrity, dimensions, largest and average pore size and permeability. Material certificates and batch, drawing, inspection and release records are part of the sintered quality evidence: name the documents your site needs when you send the enquiry.

Questions

Clarysynt replacement elements: common questions

Can you make a replacement from the old part number alone?
Send the part number with a photograph of the element and its end connection. An application engineer checks the dimensions against the Clarysynt range and asks for a drawing or a sample when the part number is not enough.
Is a Clarysynt element the same as the element it replaces?
It is a Gopani element, made to the dimensions, end connection and retention rating you specify. Fit and performance are confirmed for your process.
Can the elements be cleaned and reused?
Clarysynt PM is designed for regeneration and reuse. Backwash, blowback, chemical, ultrasonic or thermal cleaning may restore performance where the process permits. Sticky, embedded, deformable or chemically bonded contaminants may need other methods, or may make regeneration unsuitable.
Which other replacement filter cartridges does Gopani make?
Wound, meltblown, pleated, membrane, high flow and bag elements as well. The replacement filter cartridges page lists the sizes and end caps in each family.

Resources for this line

Datasheets and catalogue pages that cover Clarysynt replacement elements, sent by email on request.

Open the full library

Related products and tools

Request a quote

Send a drawing, a sample or the dimensions of the element you run now, with the end fitting, retention rating and process conditions. An application engineer confirms the Clarysynt element that fits and quotes it.

Request a quote
  • Request the catalogues

    The Clarysynt replacement elements catalogue and the rest of the sintered metal filter cartridges range, sent by email on request.

    Go to the catalogues
  • Compare the sintered metal filter cartridges range

    Clarysynt powder sintered, Clarysynt culinary steam, Clarysparge carbonation stones, Flow restrictors, Fluidizing filters, Sensor probe protection, Pneumatic silencers and mufflers, High purity and high pressure compressed air and gas filters, Clarysynt multilayer sintered mesh

    Open the family

Request a catalogue

Tell us who you are and where to send it. Our team emails the catalogue to you.

By sending this you agree to our Privacy notice.