String wound
Clarywound Extreme Bicois a bi-component wound cartridge for viscous fluids and mastics. Up to 120 °C.
A bi-component string wound cartridge for highly viscous fluids and mastics at temperatures up to 120 °C. Continuous winding forms diamond-shaped tunnels in a gradient structure, wide at the outer surface and fine at the core.

0.5 to 150 µm
Clarywound Extreme Bico OD 61, 63 or 110 mm, 9.75" to 70"
- Retention rating
- 0.5 to 150 µm
- Maximum operating temperature
- 120 °C
- Recommended change‑out ΔP
- 2.5 bar at 21 °C
- Lengths
- 9.75" to 70"
Viscous fluids
For highly viscous fluids and mastics at temperatures up to 120 °C.
Gradient structure
Diamond-shaped tunnels, wide at the outer surface and fine at the core, so the cartridge loads through its depth.
Ratings and sizes
Nine ratings from 0.5 to 150 µm, eight lengths from 9.75" to 70", in 61, 63 and 110 mm diameters.
Core and seal
Polypropylene, glass filled polypropylene, stainless steel or tinned steel cores, and four seal elastomers.
How it is built
Construction
- Continuous winding
Bico string media is wound around the core in one continuous process.
- Diamond‑shaped tunnels
The winding pattern forms tunnels in a gradient structure, wide at the outer surface.
- Fine at the core
The tunnels narrow toward the core, which sets the rating.

| Media | Bico, bi-component |
|---|---|
| Core | PP, glass filled PP, SS, tinned steel |
| Seal | Silicone, FKM, Buna-N, EPDM |
Specifications
Specification table
MaterialsMedia, core, end caps, seals
| Property | Value |
|---|---|
| Filter media | Bico, bi-component |
| Core | Polypropylene, glass filled polypropylene, SS 304 / 304L / 316 / 316L, tinned steel. Other types on request |
| End caps | Polypropylene |
| O-ring / gasket | Silicone, FKM, Buna-N, EPDM |
PerformanceRetention, temperature, pressure
| Property | Value |
|---|---|
| Retention rating | 0.5, 1, 5, 10, 20, 25, 50, 100, 150 µm |
| Maximum operating temperature | 120 °C (248 °F), Bico |
| Recommended change-out ΔP | 0.25 MPa (2.5 bar; 36.25 psid) at 21 °C |
| Surface area | ≥ 0.52 ft² standard (OD 61 mm), ≥ 0.94 ft² jumbo (OD 110 mm), per 10" cartridge length |
DimensionsDiameters and lengths
| Property | Value |
|---|---|
| OD / ID, standard | 61 ± 0.5 mm / 27.5 ± 0.5 mm |
| OD / ID, 63 mm | 63 ± 0.5 mm / 27.5 ± 0.5 mm |
| OD / ID, jumbo | 110 ± 0.5 mm / 27.5 ± 0.5 mm |
| Lengths | 9.75", 10", 20", 30", 40", 50", 60", 70" |
| Other OD and lengths | On request |
Source: Automotive industry catalogue, Clarywound Extreme Bico, pages 11 and 12 (PDF pages 12 and 13). The same specification appears in the oil cleanliness solutions (genset) catalogue, PDF page 5.
Where it runs
Where it is used
Process chemicals, photo chemicals, galvanic baths, edible oils, process water, electroplating, power generation, viscous chemicals, oils and mastics.
Send the fluid, its viscosity and temperature, the flow and the housing, and we confirm the rating, core and part number.

“Designed for viscous fluids and operating temperature up to 120 °C.”
Related products and tools
Above 120 °C
Clarywound GF is rated to 350 °C.
View Clarywound GFFiner ratings
Clarypleat PVDF is available from 0.45 µm (0.1, 0.22, 0.45 µm).
View Clarypleat PVDFChemical compatibility
A fluid checked against membrane, media, seal and housing materials at the operating temperature.
Open checkerHousings
Stainless steel, uPVC, FRP and polypropylene housings, bag vessels and skids.
View housings and systems
Request a quote
Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani cartridge.
Request a quote- Download the catalogues
The Clarywound Extreme Bico catalogue and the rest of the string wound range, as PDF.
Go to downloads - Compare the string wound range
Clarywound 3X, Clarywound Extreme, Clarywound Ultra, Clarywound CPU, Clarywound GF
Open the family