Pleated cartridges
Clarypleat PESis a sterilizing-grade PES cartridge for routine pharmaceutical and biotech liquids. ASTM F838 bacterial retention.
A single asymmetric PES membrane: a coarse upstream layer protects a fine downstream sterilizing layer. Designed for routine use in buffers, media, intermediates and final aqueous formulations. Each filter is integrity tested and traceable by serial number.

0.1, 0.2, 0.45, 1 µm
Clarypleat PES OD 69 mm, 5" to 30"
- Bacterial retention, 0.2 µm
- ≥ 10⁷ B. diminuta per cm²
- Minimum bubble point
- ≥ 3.3 bar
- Maximum air diffusion
- ≤ 18 ml at 2.6 bar
- Steam in place
- 30 cycles at 134 °C
Low protein binding
The PES membrane keeps the loss of proteins, excipients and actives during filtration low.
Bacterial retention
Meets ASTM F838 bacterial retention: ≥ 10⁷ B. diminuta per cm².
Same membrane across formats
Clarypleat PES capsules, cartridges and lab-scale formats use the same PES membrane and polymer materials.
Steam in place
30 SIP cycles at 134 °C (20 min) or at 124 °C (30 min).
How it is built
Construction
- Coarse upstream layer
Acts as a pre-filter within the membrane and protects the sterilizing layer.
- Fine downstream layer
The sterilizing layer, typically 0.2 µm, sets the retention.
- Thermally sealed
Polypropylene support and hardware, sealed without adhesives.

| Membrane | Asymmetric hydrophilic PES |
|---|---|
| Hardware | Polypropylene |
| O-ring | Silicone, EPDM |
Specifications
Specification table
MaterialsMembrane, support, hardware
| Property | Value |
|---|---|
| Membrane | Hydrophilic polyethersulfone (PES), asymmetric |
| Support layer | Polypropylene |
| Cage, core, end caps, adapters | Polypropylene |
| O-ring | Silicone, EPDM |
| Sealing | Thermal sealing, no adhesives |
IntegrityPer 10" cartridge
| Property | Value |
|---|---|
| Minimum bubble point at 25 °C | ≥ 3.3 bar, wetting liquid DI water |
| Maximum air diffusion at 25 °C | ≤ 18 ml at 2.6 bar, per 10" |
| Bacterial retention, 0.2 µm | ≥ 10⁷ Brevundimonas diminuta per cm² (ASTM F838) |
| Bacterial retention, 0.45 µm | ≥ 10⁷ Serratia marcescens per cm² |
| Integrity testing | Each filter; traceable by serial number |
Operating limitsTemperature, pressure, steam
| Property | Value |
|---|---|
| Maximum operating temperature | 80 °C continuous |
| Maximum differential pressure, forward | 5.2 bar at 25 °C |
| Maximum differential pressure, reverse | 2.1 bar at 25 °C |
| Water flow | 20 L/min at 0.2 bar, 25 °C |
| Steam in place | 30 cycles at 134 °C (20 min cycles); 30 cycles at 124 °C (30 min cycles) |
| pH | Stable filtration behaviour across pH 1 to 13 |
DimensionsLengths and area
| Property | Value |
|---|---|
| OD | 69 mm |
| Lengths | 5", 10", 15", 20", 30" |
| Effective filtration area, nominal | 0.32, 0.65, 1.0, 1.3, 1.95 m² |
Quality assuranceAs printed in the catalogue
| Property | Value |
|---|---|
| Bacterial endotoxin | ≤ 0.25 EU/ml, LAL test |
| Cytotoxicity and biological reactivity | Meets USP <87> and <88>, Class VI |
| Extractables | Evaluated per USP <661>; with WFI < 40 mg per 10" after autoclaving |
| Particulate matter | Evaluated per USP <788> |
| Fibre release | Meets 21 CFR 210.3(b)(6) |
| Flushed water | TOC ≤ 0.5 mg/l; conductivity ≤ 5.1 µS/cm |
| Indirect food additives | 21 CFR 177, (EU) No. 1935/2004, (EU) No. 10/2011 |
| Manufacturing facility | ISO 9001, ISO 14001 and ISO 45001 certified (Integrated Management System) |
Ordering codeBuild the part number field by field
| Property | Value |
|---|---|
| Pattern | CPPES- followed by micron, length, diameter, end fitting, hardware and seal codes |
| Micron | X = 0.1 µm; A = 0.2 µm; B = 0.45 µm; D = 1 µm |
| Length | 05, 10, 15, 20, 30 (inches) |
| Diameter | S = 69 mm |
| End fitting | 1 = Fin / 226; 2 = Fin / 222; 3 = Flat / 226; 4 = Flat / 222 |
| Hardware | PP = polypropylene |
| Seal | E = EPDM; S = silicone; V = Viton |
Source: Clarypleat PES catalogue, 2026, PDF pages 2 to 5. Specification table on page 4. Supplied non-sterile unless otherwise specified.
Where it runs
Buffers, media, intermediates and final aqueous formulations
Sterilizing filtration of buffers and process solutions; cell culture media and upstream process fluids; LVP, SVP and ophthalmics; intermediate and bulk drug substance; final filtration of aqueous drug products.
Utility and process filtration that supports GMP operations.

“Each filter is integrity tested and traceable by serial number.”
Questions
Clarypleat PES: common questions
- Are the filters supplied sterile?
- They are supplied non-sterile unless otherwise specified.
- Is it the same membrane as the PES capsule?
- The catalogue states that Clarypleat PES capsules, cartridges and lab-scale formats use the same PES membrane, the same polymer materials and the same construction.
- How does it differ from Kryticalpleat PES?
- Clarypleat PES is the sterilizing-grade cartridge for general process duty and runs to 30" long. Kryticalpleat PES is the range for critical applications, made with a higher grade of membrane, and runs to 40" long. Both catalogues print the same specification table.
Resources for this line
Datasheets and catalogue pages that cover Clarypleat PES, as PDF.
Related products and tools
Pre-filtration for this membrane
ClaryNira MB: meltblown pp with microban® product protection, 1 to 100 µm.
View ClaryNira MBChemical compatibility
A fluid checked against membrane, media, seal and housing materials at the operating temperature.
Open checkerHousings
Stainless steel, uPVC, FRP and polypropylene housings, bag vessels and skids.
View housings and systems
Request a quote
Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani cartridge.
Request a quote- Download the catalogues
The Clarypleat PES catalogue and the rest of the pleated cartridges range, as PDF.
Go to downloads - Compare the pleated cartridges range
Kryticalpleat PES, Kryticalpleat All Fluoropolymer, Clarypleat PTFE, Clarypleat HE, Clarypleat NE, Clarypleat CPU, Clarypleat PVDF, Clarypleat Nylon, Clarypleat 5000
Open the family