Housings and systems
Clary-T CFis a range of stainless steel cartridge housings, single and multi-round. Five configurations, nine materials.
Single and multi-round cartridge housings in SS 304, 316 and 316L, duplex, carbon and mild steel, with rubber lined options. A top-seated O-ring with positive tangential contact keeps every cartridge aligned and prevents internal bypass, and each housing is hydrostatically tested before dispatch.

0.7 MPa, higher on request
Clary-T CF 10" to 40" cartridges, 60 to 112 mm OD
- Maximum operating pressure
- 0.7 MPa, higher on request
- Maximum operating temperature
- 65 °C, higher on request
- Cartridge OD
- 60 to 112 mm
- Connections
- 1/2" to 12"
Sealed against internal bypass
A top-seated O-ring with positive tangential contact keeps the cartridges aligned and sealed.
Tested before dispatch
Each housing is hydrostatically tested before it leaves the plant.
Material for the fluid
SS 304, 316 and 316L, duplex 2205 and 2507, carbon and mild steel, and rubber lined carbon and mild steel.
Design codes
ASME Section VIII Division 1, PED 97/23/EC and CE marking, or GEP.
How it is built
Five configurations, one sealing arrangement
- Configuration
ML, M2 and U2 take DOE cartridges, inline or standard; M1 and U1 take SOE cartridges.
- Top‑seated O‑ring
Positive tangential contact holds each cartridge in line, so fluid cannot bypass it.
- Closure and finish
V-band or bolted closure; matt, mirror, electropolished or glass bead blasted surfaces.

| Cartridges | DOE, SOE (fin or flat, 222 or 226) |
|---|---|
| Closure | V-band or bolted |
| Vent and drain | NPT, BSP 1/2" to 1"; tri-clover 1/2", 1" |
Specifications
Specification table
MaterialsHousing, clamp, seals
| Property | Value |
|---|---|
| Housing | SS 304, SS 316, SS 316L, duplex SS 2205, duplex SS 2507, CS, MS, CSRL, MSRL |
| Closure clamp | SS 304 |
| O-ring | Silicone, FKM, EPDM, PTFE; others on request |
Operating limitsPressure and temperature
| Property | Value |
|---|---|
| Maximum operating pressure | 0.7 MPa (7.0 bar, 101.5 psi); higher on request |
| Maximum operating temperature | 65 °C (149 °F); higher on request |
| Design code | ASME Section VIII Division 1, GEP, PED 97/23/EC, CE marking |
| Surface finish, interior and exterior | Matt, mirror, electropolish, glass bead blasted |
ConfigurationsHousing types
| Property | Value |
|---|---|
| ML | Multi-round, double open end, inline |
| M1 | Multi-round, single open end |
| M2 | Multi-round, double open end, standard |
| U1 | Single-round, single open end |
| U2 | Single-round, double open end, inline |
| Cartridge lengths | 10", 20", 30", 40" |
| Cartridge ends | DOE; SOE Fin/222, Fin/226, Flat/222, Flat/226 |
| Inlet and outlet | BSP, NPT, DIN flange, ASA 150# flange, BS-10 Table 'D', 'E', 'F' flange, tri-clover; 1/2" to 12" |
Ordering codeBuild the part number field by field
| Property | Value |
|---|---|
| Pattern | CTCF- + housing type + design code + no. of cartridges + length + cartridge type + material + connection type + size + O-ring |
| Housing type | U1; U2; M1; M2; ML |
| Design code | A = ASME Section VIII Division 1; C = CE mark; G = GEP; P = PED |
| No. of cartridges | 3 digits |
| Cartridge length | 1 = 10"; 2 = 20"; 3 = 30"; 4 = 40" |
| Cartridge type | DOE; SOE Fin/222, Fin/226, Flat/222 or Flat/226 |
| Material | 04 = SS 304; 4L = SS 304L; 16 = SS 316; 6L = SS 316L; DL = Duplex 2205; SD = Duplex 2507; CS; MS; CL = CSRL; ML = MSRL |
| Connection type | A = ASA 150# flange; D, E, F = BS-10 Table 'D', 'E', 'F' flange; U = DIN flange; B = BSP socket; N = NPT socket; V = tri-clover |
| Connection size | 05 = 1/2"; 34 = 3/4"; 01 = 1"; 15 = 1 1/2"; 02 = 2"; 25 = 2 1/2"; 3, 4, 5, 6, 8, 10, 12 = inches |
| O-ring | B = Buna-N; E = EPDM; S = silicone; V = FKM; T = PTFE |
Source: Clary-T CF housing catalogue, 2026, p2 to p4, and the Clary-T SS All Filter Housing catalogue, 2026, p2 to p4.
Where it runs
Process liquids in stainless or coded vessels
DOE cartridges in ML, M2 or U2; SOE cartridges with 222 or 226 ends in M1 or U1.
Send us the flow, the fluid and the cartridge you run, and we size the vessel and the number of rounds.

“Each housing is hydrostatically tested prior to dispatch.”
Resources for this line
Datasheets and catalogue pages that cover Clary-T CF, as PDF.
Related products and tools
Chemical compatibility
A fluid checked against membrane, media, seal and housing materials at the operating temperature.
Open checker
Request a quote
Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani cartridge.
Request a quote- Download the catalogues
The Clary-T CF catalogue and the rest of the housings and systems range, as PDF.
Go to downloads - Compare the housings and systems range
Clary-T SF sanitary housing, Clary-T SF strainer, Clary-T HF, Clary-T Vent, Clary-T BF, Clary-T LF, ClarySEA FRP housing, Polyfilt CF, Polyfilt BF, Polyfilt HF, Plastofilt CF, Plastofilt BF, Catalyst recovery systems
Open the family