Skip to content

Housings and systems

Catalyst recovery systemsrecover precious metal catalyst in a closed circuit. Up to 99.9%, process dependent.

Single-pass, closed-circuit filtration systems for hydrogenation, recovering Pd/C, Pt/C, Rh/C, ruthenium and Raney nickel catalysts on sintered SS 316L or high nickel alloy elements. An asymmetric dual-layer element filters at the surface and backwashes at lower pressure, and integrated heel filters take the residual liquid.

Catalyst recovery systems, catalogue image

Up to 99.9% recovery

Catalyst recovery systems Sized to the process

Catalyst recovery systemsRequest a quote
Recovery, process dependent
Up to 99.9%
Catalysts
Pd, Pt, Rh, Ru, Raney Ni
Elements
Sintered SS 316L, nickel alloys
Operation
Single pass, closed circuit
  • Closed circuit

    Single-pass filtration in a closed circuit, which reduces operator exposure and fire risk.

  • Surface filtration

    An asymmetric dual-layer element holds fine catalyst on the surface, which lowers the backwash pressure needed.

  • Heel filters

    Integrated heel filters filter the residual liquid in the vessel.

  • Element testing

    Each element is tested for integrity, dimensions, largest and average pore size and permeability, with periodic corrosion and ultrasonic testing.

How it is built

How it works

  1. Filter

    Catalyst slurry passes once through sintered elements; the catalyst is held on the element surface.

  2. Backwash

    The dual-layer structure releases the cake at a lower backwash pressure.

  3. Heel

    Heel filters take the residual liquid at the end of the batch.

Catalyst recovery systems, catalogue image
ElementsSintered SS 316L, high nickel alloys, Hastelloy
StructureAsymmetric dual layer
FacilitiesIn-house CNC workshop and NDE

Specifications

Specification table

SystemAs stated

PropertyValue
RecoveryUp to 99.9%, process dependent
CatalystsPd/C, Pt/C, Rh/C, ruthenium, Raney nickel
OperationSingle-pass filtration, closed circuit
ElementsSintered SS 316L, or high nickel alloys and Hastelloy
Element structureAsymmetric dual layer for fine micron ratings, surface filtration
Element testsIntegrity, dimensions, largest and average pore size, permeability; periodic corrosion and ultrasonic tests
Production checksAlloy powder testing, micron size distribution, controlled pressure and temperature, instrument calibration
ManufacturingIn-house design workshop with CNC machines and an NDE facility; 400+ stainless steel housings a month

Source: Catalyst recovery filtration system catalogue, 2026, pages 3 to 6.

Where it runs

Where it is used

Industries in the catalogue

Pharmaceuticals and API, chemicals and fine chemicals, refining and petrochemicals, hydrogen peroxide, food and beverages, and flavours and fragrances.

Sizing

Send the catalyst, the loading, the batch volume and the solvent, and we size the system.

“Up to 99.9% recovery efficiency (process dependent).”
Catalyst recovery filtration system catalogue, 2026, page 3
See the catalogues

Resources for this line

Datasheets and catalogue pages that cover Catalyst recovery systems, as PDF.

Open the full library

Related products and tools

  • Chemical compatibility

    A fluid checked against membrane, media, seal and housing materials at the operating temperature.

    Open checker

Request a quote

Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani cartridge.

Request a quote
  • Download the catalogues

    The Catalyst recovery systems catalogue and the rest of the housings and systems range, as PDF.

    Go to downloads
  • Compare the housings and systems range

    Clary-T CF, Clary-T SF sanitary housing, Clary-T SF strainer, Clary-T HF, Clary-T Vent, Clary-T BF, Clary-T LF, ClarySEA FRP housing, Polyfilt CF, Polyfilt BF, Polyfilt HF, Plastofilt CF, Plastofilt BF

    Open the family

Download a catalogue

Tell us who you are once and every catalogue opens.

By sending this you agree to our Privacy notice.