Industry
Filtration Solutions for Water and Waste Water Treatment
One partner for the filtration points in water treatment, waste water and reuse, desalination and ultrapure water. Ahead of every membrane, the filter stage takes out the particles and colloids in the feed, and so decides how long the membrane lasts.
- Water treatmentRaw, process and utility water cleared of suspended solids before it reaches the plant and its membranes.
- Waste water and reuseEffluent screened, oil taken out and the reuse RO protected, so treated water can go back into use.Explore: Waste water and reuse
- DesalinationSeawater and brackish water brought within the feed limits of the RO, in housings that do not corrode.Explore: Desalination
- Ultrapure waterEvery point of a UPW system protected, from the RO feed to the tank vents and the point of use.Explore: Ultrapure water
Waste water and reuse
Protect the treatment train and the reuse RO, from screening to ZLD.
What filtration has to protect at each point in effluent, sewage and reuse plants. The right filter depends on the solids, any oil, and the quality the reuse train needs.
- Point 1
Screening and coarse solids
Coarse solids are taken out at the inlet, so the pumps and every stage after them are protected.Explore: Screening and coarse solids - Point 2
Oily water
Free, dispersed and emulsified oil is taken out before it reaches the filters and membranes after it, which oil fouls quickly.Explore: Oily water - Point 3
ETP and STP cartridge filtration
Effluent and sewage are filtered in housings that do not corrode, ahead of the polishing and reuse stages.Enquire: ETP and STP cartridge filtration - Point 4
Tertiary polishing
Activated carbon polishes the treated water, and a filter stage after it holds back the carbon fines.Explore: Tertiary polishing - Point 5
Reuse RO and ZLD
Pre-filters protect the reuse RO, so the membranes last and the treated water can go back into the plant.Enquire: Reuse RO and ZLD - A filtration point not shown here?Send the stage, the fluid and what you run today. An application engineer replies with what fits.Enquire
Swipe for all five points
Desalination and RO pre-filtration
Keep the RO membranes within their feed limits, from raw water to permeate.
The filter cartridge stage is the last barrier before the spiral wound elements. SDI and turbidity in the feed decide how long they last.
- Point 1
Raw water
The coarse load in seawater, brackish and process water is taken out first, so the finer stages after it last.Enquire: Raw water - Point 2
Filter cartridge pre-filtration before RO
The last barrier before the RO membranes. A stage that passes fines fouls the membranes; one that loads too fast means change-outs every few days.Explore: Filter cartridge pre-filtration before RO - Point 3
High flow pre-filtration
Large flows are carried by fewer, larger filter cartridges, so a change-out takes less time.Explore: High flow pre-filtration - Point 4
Seawater housings
Housings in FRP and uPVC stand where steel would corrode, so corrosion products do not load the filter cartridges.Explore: Seawater housings - Point 5
RO permeate and DM water
Final filters after the RO and DM plant protect the process systems the water feeds.Enquire: RO permeate and DM water - A filtration point not shown here?Send the stage, the fluid and what you run today. An application engineer replies with what fits.Enquire
Swipe for all five points
Ultrapure water
Protect high purity and ultrapure water, from make-up water to the tank vents.
Ultrapure water systems run on the same membranes as the rest of the plant, then go further: resin polishing, a closed loop and a filter at the point of use. Each UPW system is different, so an application engineer reviews yours before recommending a filter for any point.
- Point 1
Make-up water, RO and EDI
Make-up water and RO permeate are cleared of particles before the purification steps, so the membranes and the EDI see a feed they can take.Explore: Make-up water, RO and EDI - Point 2
Final filtration of HPW and UPW
The last filter before the point of use. How it flushes up, and what it adds to TOC and conductivity, matter as much as what it retains.Explore: Final filtration of HPW and UPW - Point 3
UPW tank vents
A hydrophobic vent filter on each tank keeps room air out as the level falls, and stays dry so the tank can always breathe.Explore: UPW tank vents - Ultrapure water in depthEvery filtration point of a UPW system, from the RO feed to the point of use, and the solar, semiconductor, pharma and power plants that run one.Explore: Ultrapure water in depth
Swipe for all four
Talk to an application engineer about your plant.
Name the stage, the fluid and what you see today: short filter life, haze, a rising differential pressure. We will name the filter for each filtration point.
Troubleshooting
Common challenges
What each problem looks like on the line, what usually causes it, and the first two things to check.
Desalination, filter cartridge pre-filtration
Likely causes
- A rating chosen without allowing for the solids in the feed
- A media filter upstream that is not removing what it should
- Surface-loading filter cartridges where a graded depth filter would hold more
Check first
- SDI and turbidity of the feed after the media filter
- Differential pressure at each change-out
What the right fix depends on
The feed water source and quality, the flow per housing, and the feed limits of the RO membranes.
The Gopani filter for this duty:Meltblown Filter Cartridges
Products for this industry
Filters and housings for every stage of water treatment.
Ratings, flows and test data are on each product page. An application engineer confirms the fit for your water.

Meltblown Filter Cartridges
RO Protect Extreme
RO pre-filtration.

Meltblown Filter Cartridges
RO Protect Ultra
Desalination and reuse RO.

High Flow Filter Cartridges
RO Protect HF
High flow and seawater pre-filtration.

String Wound Filter Cartridges
Clarywound Extreme
Raw and waste water.

Pleated Filter Cartridges
Clarypleat NE
Raw water.

Pleated Filter Cartridges
Clarypleat HE
Permeate and DI water.

Pleated Filter Cartridges
Clarypleat Nylon
Ultrapure water.

Filter Housings and Systems
ClarySEA FRP housing
Seawater housings.

Filter Housings and Systems
Polyfilt CF
Corrosion-free housings.
Related catalogues
Product data and test methods for the lines used in this industry, sent by email on request.
Send us one process stage. Get back the right filter, its documentation and a price.
Tell us the process stage, the fluid and the flow, and the filter you use now: a part number, a photograph or a drawing is enough. An application engineer replies with the Gopani product that fits, its documentation and a quotation.
Request a quote- Talk to an application engineer
WhatsApp or call, Monday to Saturday, IST.
Start a conversation