Skip to content

Housings and systems

Clary-T SF straineris a range of strainer housings for coarse solids. Up to 500 m³/hr, down to 23 micron.

Strainer housings that remove dirt, pipe scale and other solids from water, chemical and petroleum liquids. Single, multi, inline, duplex, back washable and dual stage designs, with the strainer held against a positive stop by a threaded centre rod.

Clary-T SF strainer, catalogue image

Up to 500 m³/hr

Clary-T SF strainer 1" to 16" connections

Clary-T SF strainerRequest a quote
Flow
Up to 500 m³/hr
Particle retention
Down to 23 micron
Operating pressure
1 to 5 bar
Temperature
-25 to 65 °C
  • Six designs

    Single, multi (2 to 16 strainers), inline, duplex, back washable and dual stage.

  • Continuous duty

    The duplex design puts a second strainer in parallel, so one runs while the other is serviced.

  • Cleaned in place

    The back washable design cleans the strainer without removing it, for high speed, low viscosity fluid.

  • Wetted parts to suit

    Stainless, duplex, carbon and mild steel, rubber lined steel, PP with FRP, or FRVE with FRP.

How it is built

Strainer element held against a positive stop

  1. Threaded centre rod

    The rod holds the strainer element against a positive stop, which prevents bypass of unfiltered liquid.

  2. Element to suit

    Cartridge, collar basket or flat strainer elements, in single or multi arrangements.

  3. Closure and lifting

    V-band, Rathmann or bolted closure; davit arm, lifting lug or handle; legs or skirt.

Clary-T SF strainer, catalogue image
ClosureV-band, Rathmann clamp, bolted
SealsSilicone, EPDM
AccessoriesPressure gauge, vent and drain valves, DP gauge

Specifications

Specification table

MaterialsWetted and non wetted

PropertyValue
WettedSS 316L, 316, 304L, 304, duplex 2205, duplex 2507, MS, CS, MSRL, CSRL, PP + FRP, FRVE + FRP
Non wettedSS 316L, 316, 304L, 304, duplex 2205, duplex 2507, MS, CS
ClampSS 304; others on request
O-ringSilicone, EPDM

Operating limitsFlow, pressure, temperature

PropertyValue
FlowUp to 500 m³/hr
Particle retentionDown to 23 micron
Operating pressure1 to 5 bar; others on request
Temperature-25 °C to +65 °C; others on request
Inlet and outlet1" to 16"
Design codeASME Section VIII Division 1, Good Manufacturing Practice
Surface finishMatt, mirror, paint; electropolish or rubber / FRP lining optional

Ordering codeBuild the part number field by field

PropertyValue
PatternCTSF- + configuration + element size + no. of elements + connection size + connection type + wetted material + non wetted material + design code
ConfigurationDO = DOE; SO = SOE; FB = flat basket; CB = cross basket; YT = Y type; CT = conical type
Element sizeSD1 to SD8 cartridge strainers; SC3 to SC24 collar baskets; SF3 to SF24 flat
No. of elements1
Connection size01 = 1"; 1H = 1.5"; 02 = 2"; 2H = 2.5"; 03 = 3"; 04 = 4"; 05 = 5"; 06 = 6"; 08 = 8"; 10 = 10"; 12 = 12"; 14 = 14"; 16 = 16"
Connection typeBF, BM = BSP (F), (M); NF, NM = NPT (F), (M); EF, DF = Table E, D flange; 5F, 3F = ASA 150#, 300# FF flange; 5R, 3R = ASA 150#, 300# SORF flange; 5W, 3W = ASA 150#, 300# WNRF flange; SM = SMS union; TC = TC end
Wetted material6L = SS 316L; S6 = SS 316; 4L = SS 304L; S4 = SS 304; D5 = Duplex 2205; D7 = Duplex 2507; MS; CS; ML = MSRL; CL = CSRL; PFR = PP + FRP; FFR = FRVE + FRP
Non wetted material6L = SS 316L; S6 = SS 316; 4L = SS 304L; S4 = SS 304; D5 = Duplex 2205; D7 = Duplex 2507; MS; CS
Design codeA8 = ASME Section VIII Division 1; NC = non coded

Source: Clary-T SF strainer housing catalogue, 2026, p2 to p5.

Where it runs

Water, process and utility lines with coarse solids

Applications in the catalogue

Water treatment, food and beverage, chemical processing, paint and ink, petrochemical, utilities, cooling water and process liquids.

Ahead of finer stages

A strainer takes coarse solids before the bag or cartridge housings downstream.

“A mechanical device with a threaded centre rod holds the strainer against a positive stop in the housing.”
Clary-T SF strainer housing catalogue, 2026
See the catalogues

Resources for this line

Datasheets and catalogue pages that cover Clary-T SF strainer, as PDF.

  • Clary-T SF housing1.5 MB · Jun 2026
    Download

Open the full library

Related products and tools

  • Chemical compatibility

    A fluid checked against membrane, media, seal and housing materials at the operating temperature.

    Open checker

Request a quote

Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani cartridge.

Request a quote
  • Download the catalogues

    The Clary-T SF strainer catalogue and the rest of the housings and systems range, as PDF.

    Go to downloads
  • Compare the housings and systems range

    Clary-T CF, Clary-T SF sanitary housing, Clary-T HF, Clary-T Vent, Clary-T BF, Clary-T LF, ClarySEA FRP housing, Polyfilt CF, Polyfilt BF, Polyfilt HF, Plastofilt CF, Plastofilt BF, Catalyst recovery systems

    Open the family

Download a catalogue

Tell us who you are once and every catalogue opens.

By sending this you agree to our Privacy notice.