Housings and systems
Clary-T SF straineris a range of strainer housings for coarse solids. Up to 500 m³/hr, down to 23 micron.
Strainer housings that remove dirt, pipe scale and other solids from water, chemical and petroleum liquids. Single, multi, inline, duplex, back washable and dual stage designs, with the strainer held against a positive stop by a threaded centre rod.

Up to 500 m³/hr
Clary-T SF strainer 1" to 16" connections
- Flow
- Up to 500 m³/hr
- Particle retention
- Down to 23 micron
- Operating pressure
- 1 to 5 bar
- Temperature
- -25 to 65 °C
Six designs
Single, multi (2 to 16 strainers), inline, duplex, back washable and dual stage.
Continuous duty
The duplex design puts a second strainer in parallel, so one runs while the other is serviced.
Cleaned in place
The back washable design cleans the strainer without removing it, for high speed, low viscosity fluid.
Wetted parts to suit
Stainless, duplex, carbon and mild steel, rubber lined steel, PP with FRP, or FRVE with FRP.
How it is built
Strainer element held against a positive stop
- Threaded centre rod
The rod holds the strainer element against a positive stop, which prevents bypass of unfiltered liquid.
- Element to suit
Cartridge, collar basket or flat strainer elements, in single or multi arrangements.
- Closure and lifting
V-band, Rathmann or bolted closure; davit arm, lifting lug or handle; legs or skirt.

| Closure | V-band, Rathmann clamp, bolted |
|---|---|
| Seals | Silicone, EPDM |
| Accessories | Pressure gauge, vent and drain valves, DP gauge |
Specifications
Specification table
MaterialsWetted and non wetted
| Property | Value |
|---|---|
| Wetted | SS 316L, 316, 304L, 304, duplex 2205, duplex 2507, MS, CS, MSRL, CSRL, PP + FRP, FRVE + FRP |
| Non wetted | SS 316L, 316, 304L, 304, duplex 2205, duplex 2507, MS, CS |
| Clamp | SS 304; others on request |
| O-ring | Silicone, EPDM |
Operating limitsFlow, pressure, temperature
| Property | Value |
|---|---|
| Flow | Up to 500 m³/hr |
| Particle retention | Down to 23 micron |
| Operating pressure | 1 to 5 bar; others on request |
| Temperature | -25 °C to +65 °C; others on request |
| Inlet and outlet | 1" to 16" |
| Design code | ASME Section VIII Division 1, Good Manufacturing Practice |
| Surface finish | Matt, mirror, paint; electropolish or rubber / FRP lining optional |
Ordering codeBuild the part number field by field
| Property | Value |
|---|---|
| Pattern | CTSF- + configuration + element size + no. of elements + connection size + connection type + wetted material + non wetted material + design code |
| Configuration | DO = DOE; SO = SOE; FB = flat basket; CB = cross basket; YT = Y type; CT = conical type |
| Element size | SD1 to SD8 cartridge strainers; SC3 to SC24 collar baskets; SF3 to SF24 flat |
| No. of elements | 1 |
| Connection size | 01 = 1"; 1H = 1.5"; 02 = 2"; 2H = 2.5"; 03 = 3"; 04 = 4"; 05 = 5"; 06 = 6"; 08 = 8"; 10 = 10"; 12 = 12"; 14 = 14"; 16 = 16" |
| Connection type | BF, BM = BSP (F), (M); NF, NM = NPT (F), (M); EF, DF = Table E, D flange; 5F, 3F = ASA 150#, 300# FF flange; 5R, 3R = ASA 150#, 300# SORF flange; 5W, 3W = ASA 150#, 300# WNRF flange; SM = SMS union; TC = TC end |
| Wetted material | 6L = SS 316L; S6 = SS 316; 4L = SS 304L; S4 = SS 304; D5 = Duplex 2205; D7 = Duplex 2507; MS; CS; ML = MSRL; CL = CSRL; PFR = PP + FRP; FFR = FRVE + FRP |
| Non wetted material | 6L = SS 316L; S6 = SS 316; 4L = SS 304L; S4 = SS 304; D5 = Duplex 2205; D7 = Duplex 2507; MS; CS |
| Design code | A8 = ASME Section VIII Division 1; NC = non coded |
Source: Clary-T SF strainer housing catalogue, 2026, p2 to p5.
Where it runs
Water, process and utility lines with coarse solids
Water treatment, food and beverage, chemical processing, paint and ink, petrochemical, utilities, cooling water and process liquids.
A strainer takes coarse solids before the bag or cartridge housings downstream.

“A mechanical device with a threaded centre rod holds the strainer against a positive stop in the housing.”
Resources for this line
Datasheets and catalogue pages that cover Clary-T SF strainer, as PDF.
- Clary-T SF housing1.5 MB · Jun 2026Download
Related products and tools
Chemical compatibility
A fluid checked against membrane, media, seal and housing materials at the operating temperature.
Open checker
Request a quote
Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani cartridge.
Request a quote- Download the catalogues
The Clary-T SF strainer catalogue and the rest of the housings and systems range, as PDF.
Go to downloads - Compare the housings and systems range
Clary-T CF, Clary-T SF sanitary housing, Clary-T HF, Clary-T Vent, Clary-T BF, Clary-T LF, ClarySEA FRP housing, Polyfilt CF, Polyfilt BF, Polyfilt HF, Plastofilt CF, Plastofilt BF, Catalyst recovery systems
Open the family