Skip to content

Filter Housings and Systems

Clary-T CF Cartridge filter housings in stainless steel, single and multi-round. Five configurations, nine materials.

Single and multi-round filter cartridge housings in SS 304, 316 and 316L, duplex, carbon and mild steel, with rubber lined options. A top-seated O-ring with positive tangential contact keeps every cartridge aligned and prevents internal bypass, and each housing is hydrostatically tested before dispatch.

Clary-T CF, catalogue image

0.7 MPa, higher on request

Clary-T CF 10" to 40" filter cartridges, 60 to 112 mm OD

Clary-T CF
Maximum operating pressure
0.7 MPa, higher on request
Maximum operating temperature
65 °C, higher on request
Filter cartridge OD
60 to 112 mm
Connections
1/2" to 12"
  • Sealed against internal bypass

    A top-seated O-ring with positive tangential contact keeps the filter cartridges aligned and sealed.

  • Tested before dispatch

    Each housing is hydrostatically tested before dispatch.

  • Material for the fluid

    SS 304, 316 and 316L, duplex 2205 and 2507, carbon and mild steel, and rubber lined carbon and mild steel.

  • Design codes

    ASME Section VIII Division 1, PED 97/23/EC and CE marking, or GEP.

How it is built

Five configurations, one sealing arrangement

  1. Configuration

    ML, M2 and U2 take DOE filter cartridges, inline or standard; M1 and U1 take SOE cartridges.

  2. Top‑seated O‑ring

    Positive tangential contact holds each filter cartridge in line, so fluid cannot bypass it.

  3. Closure and finish

    V-band or bolted closure; matt, mirror, electropolished or glass bead blasted surfaces.

Clary-T CF, catalogue image
Filter cartridgesDOE, SOE (fin or flat, 222 or 226)
ClosureV-band or bolted
Vent and drainNPT, BSP 1/2" to 1"; tri-clover 1/2", 1"

Specifications

Specification table

MaterialsHousing, clamp, seals

PropertyValue
HousingSS 304, SS 316, SS 316L, duplex SS 2205, duplex SS 2507, CS, MS, CSRL, MSRL
Closure clampSS 304
O-ringSilicone, FKM, EPDM, PTFE; others on request

Operating limitsPressure and temperature

PropertyValue
Maximum operating pressure0.7 MPa (7.0 bar, 101.5 psi); higher on request
Maximum operating temperature65 °C (149 °F); higher on request
Design codeASME Section VIII Division 1, GEP, PED 97/23/EC, CE marking
Surface finish, interior and exteriorMatt, mirror, electropolish, glass bead blasted

ConfigurationsHousing types

PropertyValue
MLMulti-round, double open end, inline
M1Multi-round, single open end
M2Multi-round, double open end, standard
U1Single-round, single open end
U2Single-round, double open end, inline
Filter cartridge lengths10", 20", 30", 40"
Filter cartridge endsDOE; SOE Fin/222, Fin/226, Flat/222, Flat/226
Inlet and outletBSP, NPT, DIN flange, ASA 150# flange, BS-10 Table 'D', 'E', 'F' flange, tri-clover; 1/2" to 12"

Ordering codeBuild the part number field by field

PropertyValue
PatternCTCF- + housing type + design code + no. of filter cartridges + length + cartridge type + material + connection type + size + O-ring
Housing typeU1; U2; M1; M2; ML
Design codeA = ASME Section VIII Division 1; C = CE mark; G = GEP; P = PED
No. of filter cartridges3 digits
Filter cartridge length1 = 10"; 2 = 20"; 3 = 30"; 4 = 40"
Filter cartridge typeDOE; SOE Fin/222, Fin/226, Flat/222 or Flat/226
Material04 = SS 304; 4L = SS 304L; 16 = SS 316; 6L = SS 316L; DL = Duplex 2205; SD = Duplex 2507; CS; MS; CL = CSRL; ML = MSRL
Connection typeA = ASA 150# flange; D, E, F = BS-10 Table 'D', 'E', 'F' flange; U = DIN flange; B = BSP socket; N = NPT socket; V = tri-clover
Connection size05 = 1/2"; 34 = 3/4"; 01 = 1"; 15 = 1 1/2"; 02 = 2"; 25 = 2 1/2"; 3, 4, 5, 6, 8, 10, 12 = inches
O-ringB = Buna-N; E = EPDM; S = silicone; V = FKM; T = PTFE

Check Clary-T CF against your duty.

Send the fluid, flow, temperature and the micron rating you need. We will confirm the fit, the size and the housing, or name the line that suits the duty better.

Where it runs

Process liquids in stainless or coded vessels

Choosing the configuration

DOE filter cartridges in ML, M2 or U2; SOE cartridges with 222 or 226 ends in M1 or U1.

Sizing

Send us the flow, the fluid and the filter cartridge you run, and we size the vessel and the number of rounds.

Industry pages

The process stages it serves, and what it protects there.

Each housing is hydrostatically tested prior to dispatch.

Request the catalogues

Resources for this line

Datasheets and catalogue pages that cover Clary-T CF, sent by email on request.

  • Clary-T CF housing4.9 MB · Sep 2026
    Request
  • Clary-T SS filter housings2.1 MB · Sep 2026
    Request

Open the full library

Related products and tools

  • Filtration Academy

    How to choose a filter housing: the seal that holds the filter cartridge rating, flow and connections, pressure and temperature, material and finish, and design code. With Gopani housing figures.

Request a quote

Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani filter cartridge.

Request a quote
  • Request the catalogues

    The Clary-T CF catalogue and the rest of the filter housings and systems range, sent by email on request.

    Go to the catalogues
  • Compare the filter housings and systems range

    Clary-T Sanitary Filter Housings, Clary-T Strainers, Clary-T HF, Clary-T Vent, Clary-T BF, Clary-T LF, ClarySEA FRP housing, Polyfilt CF, Polyfilt BF, Polyfilt HF, Plastofilt CF, Plastofilt BF, Catalyst recovery systems

    Open the family

Request a catalogue

Tell us who you are and where to send it. Our team emails the catalogue to you.

By sending this you agree to our Privacy notice.