Skip to content

Syringe and lab filters

HPLC solvent inlet filtersare sintered 316L solvent inlet filters for HPLC and UHPLC pumps. 2 and 10 µm, 0.5 µm for UHPLC.

Clarysynt-P-SF reagent and solvent inlet filters in precision sintered SS 316L, with titanium, Hastelloy C-22, PEEK and PTFE options. Slip-on, push fit and last drop designs fit the inlet lines of named Waters, Shimadzu and Agilent pumps; the 3 step tube fit design takes 1/4-28 fittings and pipe, and its 10 µm versions serve as helium spargers.

HPLC solvent inlet filters, catalogue image

0.5, 2, 10 µm

HPLC solvent inlet filters Four designs

HPLC solvent inlet filtersRequest a quote
Porosity, HPLC
2 and 10 µm
Porosity, UHPLC
0.5 µm
Maximum flow, 3 step tube fit
35 to 120 ml/min
Wetted material
SS 316L
  • Pump fit lists

    Slip-on, push fit and last drop designs list the Waters, Shimadzu and Agilent pump models they fit.

  • Sintered 316L

    Precision sintered stainless steel, with titanium and Hastelloy C-22 options.

  • Helium sparging

    The 10 µm 3 step versions are used as helium spargers to remove dissolved gases.

  • Lifetime warranty

    Against any manufacturing defect, on all Gopani HPLC repair parts.

How it is built

Four designs

  1. Universal slip‑on 1/8"

    For Waters 510 to 2695D, 2700 and ACQUITY UPLC® BSM; part CSPWSFHS16LS6SO4; wetted SS 316L.

  2. Push fit PTFE

    For Shimadzu LC-10, LC-20 and LC-30AD pumps; part CSPWSFHS16LPTFETU5; wetted SS 316L and PTFE.

  3. Last drop and 3 step tube fit

    Last drop for Agilent 1050, 1090, 1100 and 1200 (part LDP); 3 step tube fit for 1/4-28 fittings and 1/8" pipe.

HPLC solvent inlet filters, catalogue image
MediaSintered SS 316L
ConnectorsPEEK, PTFE, metal
OptionsTitanium, Hastelloy C-22

Specifications

Specification table

3 step tube fitFitting, tube, pore, maximum flow

PropertyValue
1/4-28 fitting, 1/16" tube2, 10 or 20 µm; 35 ml/min
1/4-28 fitting, 1/8" tube2 µm: 35 ml/min; 10 µm: 100 ml/min; 20 µm: 120 ml/min
Stepped, 1/16", 3/32" and 3.76 mm tube ID2, 10 or 20 µm
Pipe, 1/8", 42.5 mm body2 µm: 95 ml/min
Pipe, 1/8", 65.0 mm body2 µm: 50 ml/min; 25 µm: 100 ml/min

FitsPump models named in the catalogue

PropertyValue
Waters510, 515, 600, 610, 1515, 1525, 1525 Micro, 1525EF, 2535, 2545, 2555, 2690, 2690D, 2695, 2695D, 2700, ACQUITY UPLC® BSM
ShimadzuLC-20AD/AB, LC-10ADvp, LC-10AT, LC-10ATvp, LC-20ADXR, LC-20AR, LC-20AT, LC-30AD
Agilent1050, 1090, 1100, 1200
Slip-on installationNeeds a short piece of 1/8" ID tubing to attach to standard 1/8" OD solvent tubing

Ordering codeBuild the part number field by field

PropertyValue
PatternCSPWSF- followed by micron, size, filter material, hardware material, connector and tube size codes
PrefixCSPWSF = Clarysynt-P-SF
MicronC = 0.5 µm; E = 2 µm; G = 5 µm; H = 10 µm; I = 20 µm
SizeS1 = 126425; S2 = 126420
Filter material6L = SS 316L; HC = Hastelloy C
Hardware materialS6 = SS 316; PTFE = PTFE; X = none
ConnectorTP = tripod; SO = slip-on; TU = tube connector; X = none
Tube size1 = Ø1.75, 2.45, 3.85; 2 = Ø1.85, 2.75, 3.15; 3 = 1/16"; 4 = 1/8"; 5 = 3 mm; X = none

Source: HPLC solvent filter catalogue, edition 10 Aug 2026, PDF pages 3 to 8. Waters, ACQUITY UPLC, Shimadzu and Agilent are trademarks of their respective owners. Gopani is not affiliated with them.

Where it runs

Mobile phase inlet filtration in the HPLC lab

Where the catalogue puts it

HPLC and UHPLC mobile phase inlet filtration in pharmaceutical and analytical labs, for analytical and preparative work, and helium sparging with the 10 µm 3 step versions.

Send the pump model

Send the pump model and tube size, and we reply with the design and part number that fits.

“We extend a lifetime warranty against any manufacturing defects on all Gopani HPLC repair parts.”
HPLC solvent filter catalogue, 2026, p4
See the catalogues

Resources for this line

Datasheets and catalogue pages that cover HPLC solvent inlet filters, as PDF.

  • HPLC solvent filter1.6 MB · Sep 2026
    Download

Open the full library

Related products and tools

  • Finer ratings

    Uni.Q syringe filters is available from 0.22 µm (0.22 to 1.0 µm).

    View Uni.Q syringe filters
  • Chemical compatibility

    A fluid checked against membrane, media, seal and housing materials at the operating temperature.

    Open checker
  • Housings

    Stainless steel, uPVC, FRP and polypropylene housings, bag vessels and skids.

    View housings and systems

Request a quote

Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani cartridge.

Request a quote
  • Download the catalogues

    The HPLC solvent inlet filters catalogue and the rest of the syringe and lab filters range, as PDF.

    Go to downloads
  • Compare the syringe and lab filters range

    Uni.Q syringe filters

    Open the family

Download a catalogue

Tell us who you are once and every catalogue opens.

By sending this you agree to our Privacy notice.