Clarywound CPUis a wound polypropylene cartridge for condensate polishing in power plants. 60" and 70" long.

Wound polypropylene depth cartridges for condensate polishing units, and for RO pre-filtration, desalination pretreatment and process and make-up water. Winding pattern and controlled density give a high dirt holding capacity. 60" and 70" long at 54 mm OD, rated to 82 °C, changed out at 3.0 bar at 65 °C.

Clarywound CPU, catalogue image

1, 4, 10 µm nominal

Clarywound CPU OD 54 mm, 60" and 70"

Clarywound CPURequest a quote
Retention, nominal
1, 4, 10 µm
Flow
2.2 to 2.8 m³/hr
Change‑out ΔP
3.0 bar at 65 °C
Maximum temperature
82 °C
  • Long elements

    60" and 70" lengths for condensate polishing vessels.

  • Hot condensate

    Rated to 82 °C, with change-out at 3.0 bar at 65 °C.

  • Depth filtration

    Winding pattern and controlled density give a high dirt holding capacity with low media migration.

  • Wound or pleated

    Clarywound CPU in wound PP; Clarypleat CPU in pleated PP with backwash data.

How it is built

Construction

  1. Wound PP media

    Polypropylene wound in depth around a 28 mm ID.

  2. Long format

    60" or 70" at 54 mm OD.

  3. End caps and seal

    Stainless steel end caps with a silicone O-ring or gasket.

Clarywound CPU, catalogue image
MediaWound polypropylene
OD / ID54 ± 0.5 / 28 ± 0.5 mm
SealSilicone

Specifications

Specification table

SpecificationAs stated

PropertyValue
Retention, nominal1, 4, 10 µm
MediaWound polypropylene
End capsStainless steel
O-ring / gasketSilicone
OD / ID54 ± 0.5 mm / 28 ± 0.5 mm
Lengths60", 70"
Flow2.2 to 2.8 m³/hr
Recommended change-out ΔP3.0 bar at 65 °C
Maximum temperature82 °C (179.6 °F)

Ordering codeBuild the part number field by field

PropertyValue
PatternCWCPU followed by micron, length, diameter, end fitting, material, core and seal codes
MicronA = 1 µm; B = 4 µm; C = 10 µm
Length60 = 60"; 70 = 70"
DiameterS = 54 mm
End fitting0 = DOE
MaterialPP = polypropylene
CoreX = no core
SealS = silicone

Source: CPU series catalogue, PDF pages 3 and 4. Specification table on page 4.

Where it runs

Condensate polishing, RO and make-up water

Where the catalogue puts it

Condensate polishing in power plants; RO pre-filtration and desalination pretreatment; process and make-up water; paints and coatings, refineries and petrochemicals; microelectronics, resin and fibre filtration.

Wound or pleated

Clarypleat CPU is the pleated polypropylene alternative, absolute rated at 70 mm OD, with backwash data.

“CPU Series cartridges are engineered for condensate polishing units in power plants.”
CPU series catalogue, p3
See the catalogues

Resources for this line

Datasheets and catalogue pages that cover Clarywound CPU, as PDF.

  • Clarypleat CPU: filters for power plants0.5 MB · May 2026
    Download

Open the full library

Related products and tools

  • Above 82 °C

    Clarywound GF is rated to 350 °C.

    View Clarywound GF
  • Finer ratings

    Clarywound Ultra is available from 5 µm (5 and 10 µm).

    View Clarywound Ultra
  • Chemical compatibility

    A fluid checked against membrane, media, seal and housing materials at the operating temperature.

    Open checker
  • Housings

    Stainless steel, uPVC, FRP and polypropylene housings, bag vessels and skids.

    View housings and systems

Request a quote

Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani cartridge.

Request a quote
  • Download the catalogues

    The Clarywound CPU catalogue and the rest of the string wound range, as PDF.

    Go to downloads
  • Compare the string wound range

    Clarywound 3X, Clarywound Extreme, Clarywound Ultra, Clarywound Extreme Bico, Clarywound GF

    Open the family

Download a catalogue

Tell us who you are once and every catalogue opens.

By sending this you agree to our Privacy notice.