Filter Housings and Systems

Clary-T Vent is an electropolished vent filter housing, Ra ≤ 0.4 µm. Standard, jacketed or temperature controlled.

Vent filter housings for sterile tank venting, fermentation, pharma, food and beverage and process air and gas. The housings are electropolished and crevice free, designed for low hold-up volume, and made in three types: standard, jacketed, and jacketed with an electronic temperature controller.

Clary-T Vent, catalogue image

-25 to 135 °C

Clary-T Vent 5" to 30" filter cartridges

Clary-T Vent
Internal finish
Ra ≤ 0.4 µm
Temperature
-25 to 135 °C
Pressure rating
-1 to 7 bar
Filter cartridge lengths
5" to 30"
  • Crevice free

    Electropolished to Ra ≤ 0.4 µm (≤ 15 µinch) on the inside, which removes metal residue left by machining.

  • Jacketed types

    T2 is jacketed; T3 adds an electronic temperature controller.

  • Checked and documented

    Dimensional, weld and surface checks and a hydro test, with documentation to the relevant standard.

  • Quick fit connections

    Quick fit type connections for easy filter cartridge change-out.

How it is built

Three types: standard, jacketed, jacketed with controller

  1. T1, standard

    A standard vent filter housing.

  2. T2, jacketed

    A jacket around the housing.

  3. T3, jacketed and controlled

    A jacketed housing with an electronic temperature controller: 16 bit, 0.5 s sampling, single set point, IP65 / IP20.

Clary-T Vent, catalogue image
FinishElectropolished, Ra ≤ 0.4 µm
ConnectionsTri-clover, DIN, ASA 150#, 1/4" to 3"
SealsSilicone, EPDM

Specifications

Specification table

MaterialsHousing, clamp, seals

PropertyValue
HousingSS 304, SS 316, SS 316L, duplex SS 2205, duplex SS 2507
Closure clampSS 304
O-ringSilicone, EPDM; others on request

Operating limitsPressure, temperature, finish

PropertyValue
Pressure rating-0.1 to 0.7 MPa (-1.0 to 7.0 bar)
Temperature-25 to +135 °C (-13 to 275 °F)
Internal finishRa ≤ 0.4 µm (≤ 15 µinch)
Filter cartridgeCode-7 (226); 5", 10", 20", 30"; junior housing on request
Inlet and outletTri-clover, DIN flange, ASA 150# flange; 1/4" to 3"; others on request
Drain and ventTri-clover 1/4", 1/2", 3/4", 1"; others on request
Design codecGMP, GEP, ASME Section VIII Division 1, CE marked to PED 97/23/EC

T3 controllerElectronic temperature controller

PropertyValue
RelaySolid state, 25 A / 400 V AC
TypeSingle set point; 16 bit A/D; 0.5 s sampling
Supply and powerSwitch mode power supply; 3 VA
Data backupFlash, 10 years
Electrical connectionMini-Fit Jr. Molex, 6 pin
Bezel and displayBezel 96 × 72 mm; display height 0.36"
ProtectionIP65 / IP20

Ordering codeBuild the part number field by field

PropertyValue
PatternCTVF- + housing type + design code + length + filter cartridge type + material + connection type + size + drain/vent size + seal
Housing typeT1; T2; T3
Design codeA = ASME Section VIII Division 1; C = CE mark (PED 97/23/EC); G = cGMP
Filter cartridge length5 = 5"; 1 = 10"; 2 = 20"; 3 = 30"
Filter cartridge type1 = Fin / 226 (Code-7)
Material6L = SS 316L
Connection typeA = ASA 150# flange; V = tri-clover (V-band); U = DIN flange
Connection size14 = 1/4"; 05 = 1/2"; 34 = 3/4"; 01 = 1"; 15 = 1 1/2"; 02 = 2"; 25 = 2 1/2"; 3 = 3"
Drain / vent size14 = 1/4"; 05 = 1/2"; 34 = 3/4"; 01 = 1"
SealE = EPDM; S = silicone

Check Clary-T Vent against your duty.

Send the fluid, flow, temperature and the micron rating you need. We will confirm the fit, the size and the housing, or name the line that suits the duty better.

Where it runs

Sterile tank vents, fermenters and process gas

Applications

Sterile tank vent filtration in biopharmaceutical manufacturing, fermentation systems, pharmaceutical processing, food and beverage production, and process air and gas.

Filter cartridges to fit

Code-7 hydrophobic vent filter cartridges such as Clarypleat PTFE, 5" to 30".

Industry pages

The process stages it serves, and what it protects there.

Crevice free electropolished surface with an internal Ra value of ≤ 0.4 μm.

Request the catalogues

Resources for this line

Datasheets and catalogue pages that cover Clary-T Vent, sent by email on request.

  • Clary-T SS filter housings2.1 MB · Sep 2026
    Request
  • Clary-T Vent0.9 MB · Jun 2026
    Request

Open the full library

Related products and tools

  • Above 135 °C

    Fluidizing filters is rated to 600 °C.

  • Finer ratings

    Clarypleat HE, from 0.22 µm.

  • Filtration Academy

    How to choose a filter housing: the seal that holds the filter cartridge rating, flow and connections, pressure and temperature, material and finish, and design code. With Gopani housing figures.

Request a quote

Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani filter cartridge.

Request a quote
  • Request the catalogues

    The Clary-T Vent catalogue and the rest of the filter housings and systems range, sent by email on request.

    Go to the catalogues
  • Compare the filter housings and systems range

    Clary-T CF, Clary-T Sanitary Filter Housings, Clary-T Strainers, Clary-T HF, Clary-T BF, Clary-T LF, ClarySEA FRP housing, Polyfilt CF, Polyfilt BF, Polyfilt HF, Plastofilt CF, Plastofilt BF, Catalyst recovery systems

    Open the family

Request a catalogue

Tell us who you are and where to send it. Our team emails the catalogue to you.

By sending this you agree to our Privacy notice.