Filter Housings and Systems
Clary-T Vent is an electropolished vent filter housing, Ra ≤ 0.4 µm. Standard, jacketed or temperature controlled.
Vent filter housings for sterile tank venting, fermentation, pharma, food and beverage and process air and gas. The housings are electropolished and crevice free, designed for low hold-up volume, and made in three types: standard, jacketed, and jacketed with an electronic temperature controller.

-25 to 135 °C
Clary-T Vent 5" to 30" filter cartridges
- Internal finish
- Ra ≤ 0.4 µm
- Temperature
- -25 to 135 °C
- Pressure rating
- -1 to 7 bar
- Filter cartridge lengths
- 5" to 30"
Crevice free
Electropolished to Ra ≤ 0.4 µm (≤ 15 µinch) on the inside, which removes metal residue left by machining.
Jacketed types
T2 is jacketed; T3 adds an electronic temperature controller.
Checked and documented
Dimensional, weld and surface checks and a hydro test, with documentation to the relevant standard.
Quick fit connections
Quick fit type connections for easy filter cartridge change-out.
How it is built
Three types: standard, jacketed, jacketed with controller
- T1, standard
A standard vent filter housing.
- T2, jacketed
A jacket around the housing.
- T3, jacketed and controlled
A jacketed housing with an electronic temperature controller: 16 bit, 0.5 s sampling, single set point, IP65 / IP20.

| Finish | Electropolished, Ra ≤ 0.4 µm |
|---|---|
| Connections | Tri-clover, DIN, ASA 150#, 1/4" to 3" |
| Seals | Silicone, EPDM |
Specifications
Specification table
MaterialsHousing, clamp, seals
| Property | Value |
|---|---|
| Housing | SS 304, SS 316, SS 316L, duplex SS 2205, duplex SS 2507 |
| Closure clamp | SS 304 |
| O-ring | Silicone, EPDM; others on request |
Operating limitsPressure, temperature, finish
| Property | Value |
|---|---|
| Pressure rating | -0.1 to 0.7 MPa (-1.0 to 7.0 bar) |
| Temperature | -25 to +135 °C (-13 to 275 °F) |
| Internal finish | Ra ≤ 0.4 µm (≤ 15 µinch) |
| Filter cartridge | Code-7 (226); 5", 10", 20", 30"; junior housing on request |
| Inlet and outlet | Tri-clover, DIN flange, ASA 150# flange; 1/4" to 3"; others on request |
| Drain and vent | Tri-clover 1/4", 1/2", 3/4", 1"; others on request |
| Design code | cGMP, GEP, ASME Section VIII Division 1, CE marked to PED 97/23/EC |
T3 controllerElectronic temperature controller
| Property | Value |
|---|---|
| Relay | Solid state, 25 A / 400 V AC |
| Type | Single set point; 16 bit A/D; 0.5 s sampling |
| Supply and power | Switch mode power supply; 3 VA |
| Data backup | Flash, 10 years |
| Electrical connection | Mini-Fit Jr. Molex, 6 pin |
| Bezel and display | Bezel 96 × 72 mm; display height 0.36" |
| Protection | IP65 / IP20 |
Ordering codeBuild the part number field by field
| Property | Value |
|---|---|
| Pattern | CTVF- + housing type + design code + length + filter cartridge type + material + connection type + size + drain/vent size + seal |
| Housing type | T1; T2; T3 |
| Design code | A = ASME Section VIII Division 1; C = CE mark (PED 97/23/EC); G = cGMP |
| Filter cartridge length | 5 = 5"; 1 = 10"; 2 = 20"; 3 = 30" |
| Filter cartridge type | 1 = Fin / 226 (Code-7) |
| Material | 6L = SS 316L |
| Connection type | A = ASA 150# flange; V = tri-clover (V-band); U = DIN flange |
| Connection size | 14 = 1/4"; 05 = 1/2"; 34 = 3/4"; 01 = 1"; 15 = 1 1/2"; 02 = 2"; 25 = 2 1/2"; 3 = 3" |
| Drain / vent size | 14 = 1/4"; 05 = 1/2"; 34 = 3/4"; 01 = 1" |
| Seal | E = EPDM; S = silicone |
Check Clary-T Vent against your duty.
Send the fluid, flow, temperature and the micron rating you need. We will confirm the fit, the size and the housing, or name the line that suits the duty better.
Where it runs
Sterile tank vents, fermenters and process gas
Sterile tank vent filtration in biopharmaceutical manufacturing, fermentation systems, pharmaceutical processing, food and beverage production, and process air and gas.
Code-7 hydrophobic vent filter cartridges such as Clarypleat PTFE, 5" to 30".
The process stages it serves, and what it protects there.
Resources for this line
Datasheets and catalogue pages that cover Clary-T Vent, sent by email on request.
Related products and tools
Above 135 °C
Fluidizing filters is rated to 600 °C.
Finer ratings
Clarypleat HE, from 0.22 µm.
Filtration Academy
How to choose a filter housing: the seal that holds the filter cartridge rating, flow and connections, pressure and temperature, material and finish, and design code. With Gopani housing figures.
Request a quote
Send the part number you use today, the micron rating, flow and fluid. An application engineer replies with the matching Gopani filter cartridge.
Request a quote- Request the catalogues
The Clary-T Vent catalogue and the rest of the filter housings and systems range, sent by email on request.
Go to the catalogues - Compare the filter housings and systems range
Clary-T CF, Clary-T Sanitary Filter Housings, Clary-T Strainers, Clary-T HF, Clary-T BF, Clary-T LF, ClarySEA FRP housing, Polyfilt CF, Polyfilt BF, Polyfilt HF, Plastofilt CF, Plastofilt BF, Catalyst recovery systems
Open the family