Basics of Filtration

 
 
Cartridge Filter Driving Forces
 
Parallel Piping
 


Total Flow Rate = Flow Rate A + Flow Rate B + Flow Rate C
PA = PB = PC
 
Series Filtration


Total P = PA + PB + PC NOTE : The overall P of the series system is also figured by subtracting the outlet pressure from the inlet pressure.
Maximum Recommended Operating Temperatures
 
 
Gasket Material Buna N 250o F (121o C)
Ethylene Propylene 350o F (177o C)
Viton 450o F (232o C)
Teflon 500o F (260o C)
Filter Media Polyester 300o F (149o C)
Polypropylene 225o F (107o C)
Nylon 325o F (163o C)
Housing Media Carbon Steel 400o F (204o C)
304 Stainless Steel 400o F (204o C)
316 Stainless Steel 400o F (204o C)
PVC 150o F (65o C)
Polypropylene 150o F (65o C)
 
 
       